DEVI DEVIreg Touch Guía de instalación

Busca en linea o descarga Guía de instalación para Termostatos DEVI DEVIreg Touch. DEVI DEVIreg Touch Installation guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
DEVIreg™ Touch
Electronic Intelligent Timer Thermostat
Installation Guide
www.DEVI.com
PLEASE DO NOT TRY TO ASSEMBLE THIS THERMOSTAT BEFORE FULLY READING THROUGH THE INSTRUCTIONS
AND UNTIL THE TIME OF INSTALLATION. Please note that disassembly can be challenging and should be avoided
to ensure against the damage to any individual part or the thermostat as a whole.
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - DEVIreg™ Touch

DEVIreg™ TouchElectronic Intelligent Timer ThermostatInstallation Guidewww.DEVI.comPLEASE DO NOT TRY TO ASSEMBLE THIS THERMOSTAT BEFORE FULLY READING

Pagina 2

Follow the steps below to mount the thermostat:1. Open the thermostat:Important: Do NOT press on the display screen whenremoving the front part.(botto

Pagina 3

The screen of the heating cable must be connected tothe earth conductor of the power supply cable by us-ing a separate connector.Note: Always instal

Pagina 4

Initially it is recommended to leave the thermostat connectedto the main supply for 15 hours to fully charge the battery. The current time and day is

Pagina 5

2. Press the hour numbersand use the < and > ar-rows to set the hour.Press to conrm.3. Press the minutes num-bers and use the < and >arr

Pagina 6

6. On the SETUP informa-tion screen, press tostart.7. Use the < and > arrowsto select whether only afloor sensor or a combi-nation of room and

Pagina 7

9. Use the < and > arrowsto select the ooringtype. Press to conrm.10. Use the < and > arrowsto select the room type.Press to conrm.11

Pagina 8

12. Use the < and > arrowsto select whether thetimer should be activatedor not. Press to con-rm and end the initialthermostat setup. SkipStep

Pagina 9

The forecast feature also optimises heating stop whenswitching from comfort temperature to economy tempera-ture.How to turn the forecast feature on an

Pagina 10

3. Press FORECAST. Thenpress ON to optimiseheating start/stop or OFFto simply let the heatingstart/stop at the specifiedtime. Press to confirm. To

Pagina 11

3. Press WINDOW OPEN.Then press ON to tempo-rarily turn off heating incase of a sudden temper-ature drop in the room orOFF to let the thermostatheat d

Pagina 13

2. Press SETTINGS in thebottom right corner ofthe menu. Then press IN-STALLATION and MAN-UAL SETUP.3. Press MAX. FLOOR. Thenuse the < and > arro

Pagina 14

If you break the small plasticseal on the back of the displaymodule, e.g. using a screw-driver, it will be possible to setture up to 45°. Furthermore,

Pagina 15

Ther-malresist-ance[m2K/W]Examples of floor-ingDetails Approximatesetting for 25˚Cfloor tempera-ture0.05 8 mm HDF basedlaminate> 800kg/m328˚C0.10 1

Pagina 16

4 SymbolsThe following symbols may appear in the upper left cornerof the temperature display:Sym-bolWhat it meansThe thermostat is in manual mode, i.e

Pagina 17

5 Warranty5Y E A R6 Disposal InstructionDEVIreg™ Touch24 Installation Guide

Pagina 18

DEVIreg™ TouchInstallation Guide 25

Pagina 19

DEVIreg™ Touch26 Installation Guide

Pagina 20

DEVIreg™ TouchDanfoss A/SElectric Heating SystemsUlvehavevej 617100 VejleDenmarkPhone: +45 7488 8500Fax: +45 7488 8501E-mail: [email protected]

Pagina 21

DEVIreg Touch Design Frame140F1064Intelligent TimerThermostatFloor / Room Sensor220-240V~50-60Hz~0 to +30°C16A/3680W@230V~IP 21Product DocumentationDK

Pagina 22

Table of Contents1 Introduction ... 31.1 Technical Specifications ... 41.2 Safety Instructions ... 72 Mounting Instructions ...

Pagina 23

▪An installation wizard with room/floor type-specificsetup.▪Support for multiple frame systems.▪Compatible with several 3rd party NTC sensors.▪Thermos

Pagina 24

Sensing units NTC 6.8 kOhm at 25°CNTC 10 kOhm at 25°CNTC 12 kOhm at 25°CNTC 15 kOhm at 25°C (Default)NTC 33 kOhm at 25°CNTC 47 kOhm at 25°CSensing val

Pagina 25

Sensor failure moni-toringThe thermostat has a built-inmonitoring circuit, which willswitch off the heating if the sen-sor is disconnected or short-ci

Pagina 26

1.2 Safety Instructionsbefore installation.IMPORTANT: When the thermostat is used to control ato determine suitable temperature settings (it isrestric

Pagina 27

2 Mounting InstructionsPlease observe the following placement guidelines:Place the thermostat at a suitable height onthe wall (typically 80-170cm.).Th

Pagina 28 - DEVIreg Touch Design Frame

Note: A oor sensor enables a more accuratetemperature control and is recommended inall oor heating applications and mandatoryunder wooden oors to r

Comentarios a estos manuales